STSG/STSO Hi-Fin

Saves your fuel expenses by adopting eco-friendly turbo spiral burner.

STSG/STSO Hi-Fin

Masterpiece made from 40 years of Kiturami craftsmanship

  • Forced draft structure, which keeps furnace pressure higher than atmospheric pressure and pushes combusted gas into flue, to control low temperature corrosion symptom and scaling which are weak points of natural draft type boiler structure
  • Because hot water pipe made of high-end stainless material was applied to insulated hot water tank for Korean Ondol system, sufficient amount of water is provided and its hot water heat exchanger is just secure from blockage due to foreign substances.
  • A special Hi Fin fire tube and baffle were adopted to promote heat transfer.
  • Safe boiler by adopting a cutting-edge automatic control functions such as overheating detection, low-water detection, etc.
  • Turbo spiral burner re-combusts primary combusted gas by using a special metal plate heated at 800°C. This new eco-friendly technology improves combustion efficiency and reduces fuel cost.

Slim design, advanced concept boiler

  • The finest stainless material with no stress corrosion and crack was applied to have outstanding durability. Compared with standing iron boiler, this compact and slim boiler with high-efficiency heat exchanger design is easy to move and install thanks to its reduced boiler volume and weight.
스텐레스하이핀중형.png

Internal Structure

  • 1) Spiral gas/oil burner

    Eco-friendly burner which achieved low CO and smoke density under 1

  • 2) A special Hi Fin fire tube to promote heat transfer

    Instead of old pipe-type fire tubes, special Hi Fin fire tube with a wider heating surface is used to promote heat transfer and enhance boiler efficiency significantly. Additionally, the boiler has slim specifications, thanks to the reduced number of fire tubes in the boiler.

  • 3) Selectable gas /oil model

    Use turbo spiral oil burner for oiler boiler, use turbo spiral gas burner for gas boiler

  • 4) Auto controller

  • 5) Steel frame with which to move and install

  • 6) Sufficient amount of hot water in heating tank (storage type tank)

Room Temperature Controller with Various Functions (CTR-5700PLUS)

You can use various functions including leave, bath, schedule, etc. through very intuitive room controller.

Untitled-4.png

Conventional Stainless Hi Fin Boiler Vs. New Stainless Hi Fin Medium Boiler

hp.png

Kiturami, with a half century of history,
is Korea's No. 1 boiler!

Korea-leading company, Kiturami Boiler has grown up based on customer trust.
Now, we move ahead to the world.

Kiturami Boiler Promotion Movie Clip

  • 2016년 18년 연속 가정용보일러 브랜드파워 1위
  • 2007년 9년 연속 품질 경쟁력 우수기업 수상
  • 2015년 15년 연속 여성소비자가 뽑은 좋은 기업 대상
  • 2007년 KS제품 품질 우수 기업 선정
  • 2016년 9년 연속 국가브랜드 경쟁력지수 1위
  • 2009년 가정용보일러A/S부문 서비스품질 1위
가스보일러
Type Unit Combi(heating + DHW)
Item Stainless Hi Fin - 50 Stainless Hi Fin - 70 Stainless Hi Fin - 100
Rated output Heating kcal/h(kW) 50,000(58.1) 70,000(81.4) 100,000(116.3)
Hot Water kcal/h(kW) 50,000(58.1) 70,000(81.4) 100,000(116.3)
Type - Floor standing, Semi-Closed, FE
Fuel - LNG(town gas), 13A / LPG
Fuel consumption kcal/h(kW) 61,500(71.50) 85,000(98.8) 122,000(141.9)
Heating surface area 2.89 3.65 4.23
Operating flow rate 46 54 62
Gas pressure kPa(kgf/mmH2O) 2.0+0.5(200+50,-100) / 2.8+0.5, -0.5(280+50, -50)
Efficiency Heating(total) % LNG : 90(84) / LPG : 90(84) LNG : 90(84) / LPG : 90(84) LNG : 90(84) / LPG : 90(84)
Hot Water(total) % LNG : 90(84) / LPG : 90(84) LNG : 90(84) / LPG : 90(84) LNG : 90(84) / LPG : 90(84)
Min. Operating pressure Heating kPa(kgf/㎠) 343.2(35)
Hot Water kPa(kgf/㎠) 98~980(1~10)
Connections Heating A 40 40 40
Hot Water A 20 20 25
Gas inlet A 20 20 20
Flue ø 125 125 125
Outer case dimension WXHXD W x L x H 532 x 742 x 1057 532 x 742 x 1186 570 x 780 x 1190
Weight kg 77 85 106
Electric Supply V AC 220V, 60Hz
기름보일러
Type Unit Combi(heating + DHW)
Item Stainless Hi Fin - 50 Stainless Hi Fin - 70 Stainless Hi Fin - 100
Rated output Heating kcal/h(kW) 50,000(58.1) 70,000(81.4) 100,000(116.3)
Hot Water kcal/h(kW) 50,000(58.1) 70,000(81.4) 100,000(116.3)
Type - Floor standing, Semi-Closed, FE
Fuel - light oil, kerosene
Fuel consumption kcal/h(kW) 6.8 9.5 13.4
Heating surface area 2.89 3.65 4.23
Operating flow rate 46 54 62
Efficiency Heating(total) % 90(84) 90(84) 90(84)
Hot Water(total) % 90(84) 90(84) 90(84)
Min. Operating pressure Heating MPa(kgf/㎠) 343.2(35)
Hot Water MPa(kgf/㎠) 98~980(1~10)
Connections Heating A 40 40 40
Drain A 20 20 25
Flue ø 125 125 125
Outer case dimension WXHXD W x L x H 532 x 742 x 1057 532 x 742 x 1190 570 x 780 x 1190
Weight kg 77 85 106
Electric Supply V AC 220V, 60Hz
  • ※ Design and specification might be changed for improving quality without notice and the data is stated by KITURAMI R&D
고객지원 링크
(0개)
(0개)
View List
본 웹사이트의 게제된 모든 이메일 주소의 무단수집을 거부하며, 자세한 내용은 하단을 참고하시기 바랍니다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나 그밖의 기술적 장치를 이용하여 무단 수집되는 것을 거부하며, 이를 위반시 정보통신망법에 의해 형사처벌됨을 유념하시기 바랍니다.
이메일을 기술적 장치를 이용하여 무단으로 수집, 판매, 유통하거나 이를 이용한자는 「정보통신망 이용촉진 및 정보보호」등에 관한 법률 제 50조의 2규정에 의하여 1천만원 이하의 벌금형에 처해집니다.

01. 누구든지 전자우편주소의 수집을 거부하는 의사가 명시된 인터넷 홈페이지에서 자동으로 전자우편주소를 수집하는 프로그램, 그 밖의 기술적 장치를 이용하여 전자우편주소를 수집하여서는 아니된다.
02. 누구든지 제1항의 규정을 위반하여 수집된 전자우편주소를 판매·유통 하여서는 아니된다.
03. 누구든지 제1항 및 제2항의 규정에 의하여 수집/판매 및 유동이 금지된 전자우편주소임을 알고 이를 정보전송에 이용하여서는 아니된다.